From 1a767f256fb239b778b39ffb000e8341f986edca Mon Sep 17 00:00:00 2001 From: tannevaled Date: Mon, 23 Nov 2026 20:48:48 +0100 Subject: [PATCH] vm: map every Win32 and Winsock code through MRI's errmap (#980) On Windows a syscall.Errno is the Win32 code itself, and errnoClasses is keyed by the numbers Go gives the POSIX names, so every raiser that looked a failed call's number up directly picked an unrelated class, or none. ERROR_PATH_NOT_FOUND (3) is Go's syscall.ENOTDIR there, so a path through a missing directory read as Errno::ENOTDIR where MRI raises Errno::ENOENT (witnessed on #978's Windows runner, for the flush), and rmdir of a non-empty directory (ERROR_DIR_NOT_EMPTY) fell to Errno::ENOENT. MRI maps the code first, through errmap and rb_w32_map_errno (win32/win32.c:145-300, v4.0.9). errnoOfError now does the same, once, so sysFail, chdir, realpath, pwrite, the flush and the dial error all see MRI's class. errIsErrno falls back on the mapped class, so ERROR_DIR_NOT_EMPTY is ENOTEMPTY for rmdir, and the two direct errors.Is(err, syscall.EINVAL) checks (File.truncate, flock) go through it. The Winsock rows are ported in full (43, where posixErrno held 15), and posixErrno is gone. Eight of their classes have no number in rbgo on any target (ESHUTDOWN, ETOOMANYREFS, EHOSTDOWN, EPFNOSUPPORT, ESOCKTNOSUPPORT, EPROCLIM, EUSERS, EREMOTE); those keep the WSA code and raise SystemCallError, as before. TestWSARowsWithoutAClass pins that list. Everywhere but Windows mapHostErrno is the identity. Fixes #980 Co-Authored-By: Claude Opus 5.5 --- README.md | 1 + internal/vm/errno_host.go | 27 ++++- internal/vm/errno_mapped_test.go | 45 +++++++++ internal/vm/errno_win32_windows.go | 99 +++++++++++++++++-- .../vm/errno_win32_windows_internal_test.go | 57 ++++++++++- internal/vm/errno_winsock_other.go | 15 --- internal/vm/errno_winsock_windows.go | 69 ------------- internal/vm/file.go | 4 +- internal/vm/io.go | 3 +- internal/vm/io_dirty.go | 3 +- internal/vm/socket_dialerr.go | 10 +- 11 files changed, 219 insertions(+), 114 deletions(-) create mode 100644 internal/vm/errno_mapped_test.go delete mode 100644 internal/vm/errno_winsock_other.go delete mode 100644 internal/vm/errno_winsock_windows.go diff --git a/README.md b/README.md index 110d161d..0ee8b120 100644 --- a/README.md +++ b/README.md @@ -906,6 +906,7 @@ What a target lacks, rbgo leaves out the way MRI does: - **The store gems** — SQLite3, Sequel, ActiveRecord's adapter, Bolt, Bleve, Etcd and Confd — need modernc.org/sqlite, which has a port for darwin/{amd64,arm64}, freebsd/{386,amd64,arm,arm64}, linux/{386,amd64,arm,arm64,loong64,ppc64le,riscv64,s390x}, netbsd/amd64, openbsd/{amd64,arm64} and windows. Elsewhere (wasm included) `require` still works and the modules exist, and the first real operation raises `NotImplementedError: sqlite3 is not supported on linux/mips64le` (or the gem and target in question). - **Errno**: a name the system's `` lacks is still a constant, naming `Errno::NOERROR`, as MRI's `undefined_error` does: `EMULTIHOP` and `ENOLINK` on OpenBSD, `ENOTRECOVERABLE` and `EOWNERDEAD` on NetBSD and DragonFly. +- **Errno on Windows**: a failed call's Win32 or Winsock code picks its class through MRI's own table (`errmap` and `rb_w32_map_errno` in `win32/win32.c`), so a missing directory is `Errno::ENOENT` and a refused connection `Errno::ECONNREFUSED`, as under MRI; a Win32 code absent from the table is `Errno::EINVAL`. Eight Winsock rows (`ESHUTDOWN`, `ETOOMANYREFS`, `EHOSTDOWN`, `EPFNOSUPPORT`, `ESOCKTNOSUPPORT`, `EPROCLIM`, `EUSERS`, `EREMOTE`) name classes rbgo has no number for on any target, so those failures raise plain `SystemCallError` ([#980](https://github.com/go-embedded-ruby/ruby/issues/980)). - **`Process::RLIMIT_*`** exist only where the system has the resource: no `RLIMIT_AS` on OpenBSD, no `RLIMIT_MEMLOCK` on AIX, only `RLIMIT_AS` of the four optional ones on Solaris and illumos. - **`File#flock`** and PStore's lock use `flock(2)`; AIX has none, so there it is emulated with `fcntl(2)` record locks, exactly as MRI's `missing/flock.c` does. - **plan9 (386, amd64, arm) compiles and vets, and is untested at run time.** Its `syscall` package has no errno numbers (`syscall.EINVAL` is a string error there), no `Kill`, `Flock`, `Getrlimit`, `Umask` or `Stat_t`, so rbgo has a plan9 variant of each seam. Nothing has been run on a Plan 9 kernel; the one part with tests is the error-string mapping, which is pure Go and runs on every platform. What that means: diff --git a/internal/vm/errno_host.go b/internal/vm/errno_host.go index 326d5646..86629ce0 100644 --- a/internal/vm/errno_host.go +++ b/internal/vm/errno_host.go @@ -16,20 +16,37 @@ import ( // *os.SyscallError, *net.OpError …). ok is false for an error with no errno // behind it. The Plan 9 counterpart (errno_plan9.go) has no numbers to dig out and // derives one from the error string instead. +// +// The number is the one of the class MRI raises, which on Windows is not the +// code the call failed with: a Windows syscall.Errno is the Win32 code itself, +// and MRI maps it through rb_w32_map_errno before anything raises it, so +// ERROR_PATH_NOT_FOUND (3) is Errno::ENOENT. mapHostErrno does that mapping +// there and is the identity elsewhere. Doing it here, once, means no raiser can +// look a raw Win32 code up in errnoClasses (go-embedded-ruby/ruby#980). +// +// ⚠ Windows: Go defines syscall.ENOENT as ERROR_FILE_NOT_FOUND (2) and +// syscall.ENOTDIR as ERROR_PATH_NOT_FOUND (3), so an ENOTDIR that Go builds +// itself (os.MkdirAll through a file, os.ReadDir on one, filepath.EvalSymlinks) +// is the very number Windows uses for a missing path, and is mapped to ENOENT +// as MRI maps that code. No raiser here takes its error from those three +// today; one that does must decide the class itself. func errnoOfError(err error) (int64, bool) { var eno syscall.Errno if errors.As(err, &eno) { - return int64(eno), true + return mapHostErrno(int64(eno)), true } return 0, false } // errIsErrno reports whether err is the Errno class `name` (an errnoNumbers key): -// errors.Is against the host's syscall.Errno of that number, so it answers exactly -// what errors.Is(err, syscall.) would. It exists so the call sites compile -// on Plan 9, whose syscall package lacks most of those constants. +// whether errnoOfError maps it to that class's number. Off Windows that is +// errors.Is(err, syscall.) for the first errno in the chain; on Windows +// it also sees that ERROR_DIR_NOT_EMPTY is ENOTEMPTY, which errors.Is cannot. +// It exists so the call sites compile on Plan 9, whose syscall package lacks +// most of those constants. func errIsErrno(err error, name string) bool { - return errors.Is(err, syscall.Errno(errnoNumbers[name])) + eno, ok := errnoOfError(err) + return ok && eno == errnoNumbers[name] } // errnoText is the message sysFail embeds for an errno: errnoMessage of the host's diff --git a/internal/vm/errno_mapped_test.go b/internal/vm/errno_mapped_test.go new file mode 100644 index 00000000..587c624b --- /dev/null +++ b/internal/vm/errno_mapped_test.go @@ -0,0 +1,45 @@ +// Copyright (c) the go-embedded-ruby/ruby authors +// +// SPDX-License-Identifier: BSD-3-Clause + +package vm_test + +import "testing" + +// TestAFailedCallRaisesMRIsClassOnEveryHost (go-embedded-ruby/ruby#980): the +// expected output is MRI 4.0.7's on darwin, and MRI raises the same classes on +// Windows because it maps each Win32 code through errmap first. These are the +// rows where the raw Win32 code named another class, or none: +// +// - a path through a missing directory fails with ERROR_PATH_NOT_FOUND (3), +// which is Go's syscall.ENOTDIR on Windows, so it read as Errno::ENOTDIR; +// - rmdir of a non-empty directory fails with ERROR_DIR_NOT_EMPTY (145), +// which errors.Is never matched to ENOTEMPTY, so it fell to Errno::ENOENT. +// +// On the POSIX lanes these pass with or without the mapping; the Windows lane +// is the one that says whether it holds. +func TestAFailedCallRaisesMRIsClassOnEveryHost(t *testing.T) { + checkCases(t, []runCase{ + {`require "tmpdir" +Dir.mktmpdir do |d| + begin + Dir.chdir(File.join(d, "missing", "sub")) + rescue SystemCallError => e + p e.class + end + full = File.join(d, "full") + Dir.mkdir(full) + File.write(File.join(full, "f"), "x") + begin + Dir.rmdir(full) + rescue SystemCallError => e + p e.class + end + begin + File.truncate(File.join(d, "missing", "sub"), 0) + rescue SystemCallError => e + p e.class + end +end`, "Errno::ENOENT\nErrno::ENOTEMPTY\nErrno::ENOENT\n"}, + }) +} diff --git a/internal/vm/errno_win32_windows.go b/internal/vm/errno_win32_windows.go index c5cfa809..7341b2ab 100644 --- a/internal/vm/errno_win32_windows.go +++ b/internal/vm/errno_win32_windows.go @@ -20,9 +20,7 @@ import ( // // ERROR_INVALID_HANDLE appears twice in errmap, as EBADF and then EINVAL; the // first row is the one rb_w32_map_errno's loop returns, so it alone is here. -// The WSA rows are left out: their codes are at or above WSABASEERR, which -// mapHostErrno keeps as they are, as rb_w32_map_errno does for a WSA code -// absent from the table. +// The WSA rows are wsaErrnos. var win32Errnos = map[syscall.Errno]string{ windows.ERROR_INVALID_FUNCTION: "EINVAL", windows.ERROR_FILE_NOT_FOUND: "ENOENT", @@ -111,19 +109,102 @@ var win32Errnos = map[syscall.Errno]string{ windows.ERROR_CANT_RESOLVE_FILENAME: "ELOOP", } -// wsaBaseErr is WSABASEERR: from there up a code is a socket error, or one of -// the numbers Go invented for the POSIX names, and is kept as it is. +// wsaErrnos is the rest of MRI's errmap (win32/win32.c:235-277, v4.0.9): the +// Winsock rows, all 43 of them, in errmap's order. A socket call fails with +// one of these, so without them a refused connection is a bare +// SystemCallError where MRI raises Errno::ECONNREFUSED. +// +// Eight targets (EHOSTDOWN, EPFNOSUPPORT, EPROCLIM, EREMOTE, ESHUTDOWN, +// ESOCKTNOSUPPORT, ETOOMANYREFS, EUSERS) have no number in rbgo on any +// target (errnoUndefinedEverywhere), so no class to land in: mapHostErrno +// keeps the WSA code for them, which raises SystemCallError, until the +// per-platform errno tables define them. TestWSARowsWithoutAClass pins that +// list, so defining one shows up there. +var wsaErrnos = map[syscall.Errno]string{ + windows.WSAEINTR: "EINTR", + windows.WSAEBADF: "EBADF", + windows.WSAEACCES: "EACCES", + windows.WSAEFAULT: "EFAULT", + windows.WSAEINVAL: "EINVAL", + windows.WSAEMFILE: "EMFILE", + windows.WSAEWOULDBLOCK: "EWOULDBLOCK", + windows.WSAEINPROGRESS: "EINPROGRESS", + windows.WSAEALREADY: "EALREADY", + windows.WSAENOTSOCK: "ENOTSOCK", + windows.WSAEDESTADDRREQ: "EDESTADDRREQ", + windows.WSAEMSGSIZE: "EMSGSIZE", + windows.WSAEPROTOTYPE: "EPROTOTYPE", + windows.WSAENOPROTOOPT: "ENOPROTOOPT", + windows.WSAEPROTONOSUPPORT: "EPROTONOSUPPORT", + windows.WSAESOCKTNOSUPPORT: "ESOCKTNOSUPPORT", + windows.WSAEOPNOTSUPP: "EOPNOTSUPP", + windows.WSAEPFNOSUPPORT: "EPFNOSUPPORT", + windows.WSAEAFNOSUPPORT: "EAFNOSUPPORT", + windows.WSAEADDRINUSE: "EADDRINUSE", + windows.WSAEADDRNOTAVAIL: "EADDRNOTAVAIL", + windows.WSAENETDOWN: "ENETDOWN", + windows.WSAENETUNREACH: "ENETUNREACH", + windows.WSAENETRESET: "ENETRESET", + windows.WSAECONNABORTED: "ECONNABORTED", + windows.WSAECONNRESET: "ECONNRESET", + windows.WSAENOBUFS: "ENOBUFS", + windows.WSAEISCONN: "EISCONN", + windows.WSAENOTCONN: "ENOTCONN", + windows.WSAESHUTDOWN: "ESHUTDOWN", + windows.WSAETOOMANYREFS: "ETOOMANYREFS", + windows.WSAETIMEDOUT: "ETIMEDOUT", + windows.WSAECONNREFUSED: "ECONNREFUSED", + windows.WSAELOOP: "ELOOP", + windows.WSAENAMETOOLONG: "ENAMETOOLONG", + windows.WSAEHOSTDOWN: "EHOSTDOWN", + windows.WSAEHOSTUNREACH: "EHOSTUNREACH", + windows.WSAEPROCLIM: "EPROCLIM", + windows.WSAENOTEMPTY: "ENOTEMPTY", + windows.WSAEUSERS: "EUSERS", + windows.WSAEDQUOT: "EDQUOT", + windows.WSAESTALE: "ESTALE", + windows.WSAEREMOTE: "EREMOTE", +} + +// wsaBaseErr is WSABASEERR: from there up a code absent from errmap is a +// socket error MRI has no class for, or one of the numbers Go invented for the +// POSIX names, and is kept as it is. const wsaBaseErr = 10000 // mapHostErrno is rb_w32_map_errno: the errno number of the class MRI raises // for the Win32 code eno. A code in errmap gets its class; a code at or above -// WSABASEERR is kept; any other code is EINVAL. +// WSABASEERR is kept; any other code is EINVAL. A row whose class rbgo has no +// number for keeps the code too (see wsaErrnos). func mapHostErrno(eno int64) int64 { - if eno == 0 || eno >= wsaBaseErr { + if eno == 0 { + return 0 + } + name, ok := win32Errnos[syscall.Errno(eno)] + if !ok { + name, ok = wsaErrnos[syscall.Errno(eno)] + } + if ok { + if n, ok := errnoNumberOf(name); ok { + return n + } return eno } - if name, ok := win32Errnos[syscall.Errno(eno)]; ok { - return errnoNumbers[name] + if eno >= wsaBaseErr { + return eno } return errnoNumbers["EINVAL"] } + +// errnoNumberOf is the number of the Errno class `name` names on this target: +// its own, or the one an alias (EWOULDBLOCK) shares. ok is false for a name +// with no number here. +func errnoNumberOf(name string) (int64, bool) { + if n, ok := errnoNumbers[name]; ok { + return n, true + } + if a, ok := errnoAliases[name]; ok { + n, ok := errnoNumbers[a] + return n, ok + } + return 0, false +} diff --git a/internal/vm/errno_win32_windows_internal_test.go b/internal/vm/errno_win32_windows_internal_test.go index dc901881..6dd2e3c3 100644 --- a/internal/vm/errno_win32_windows_internal_test.go +++ b/internal/vm/errno_win32_windows_internal_test.go @@ -7,6 +7,7 @@ package vm import ( + "os" "syscall" "testing" @@ -35,6 +36,14 @@ func TestMapHostErrnoIsRbW32MapErrno(t *testing.T) { {windows.ERROR_INVALID_NAME, "EINVAL"}, // A number Go invented for a POSIX name: kept. {syscall.ENOENT, "ENOENT"}, + // The Winsock rows (go-embedded-ruby/ruby#980). + {windows.WSAECONNRESET, "ECONNRESET"}, + {windows.WSAECONNREFUSED, "ECONNREFUSED"}, + {windows.WSAENOTSOCK, "ENOTSOCK"}, + {windows.WSAEMSGSIZE, "EMSGSIZE"}, + {windows.WSAENOTEMPTY, "ENOTEMPTY"}, + // EWOULDBLOCK is a second name for EAGAIN's class in rbgo. + {windows.WSAEWOULDBLOCK, "EAGAIN"}, } for _, c := range cases { if got := mapHostErrno(int64(c.eno)); got != errnoNumbers[c.want] { @@ -44,7 +53,51 @@ func TestMapHostErrnoIsRbW32MapErrno(t *testing.T) { if got := mapHostErrno(0); got != 0 { t.Errorf("mapHostErrno(0) = %d, want 0", got) } - if got := mapHostErrno(int64(windows.WSAECONNRESET)); got != int64(windows.WSAECONNRESET) { - t.Errorf("a WSA code was changed to %d", got) + // A WSA code absent from errmap is kept, as rb_w32_map_errno keeps it. + if got := mapHostErrno(int64(windows.WSAEDISCON)); got != int64(windows.WSAEDISCON) { + t.Errorf("WSAEDISCON was changed to %d", got) + } +} + +// TestWSARowsWithoutAClass pins the errmap rows whose class rbgo has no number +// for: mapHostErrno keeps their WSA code. Defining one of those names on +// Windows moves it out of this list, and the test says which. +func TestWSARowsWithoutAClass(t *testing.T) { + want := map[string]bool{ + "EHOSTDOWN": true, "EPFNOSUPPORT": true, "EPROCLIM": true, "EREMOTE": true, + "ESHUTDOWN": true, "ESOCKTNOSUPPORT": true, "ETOOMANYREFS": true, "EUSERS": true, + } + if len(wsaErrnos) != 43 { + t.Errorf("wsaErrnos has %d rows; errmap has 43 Winsock rows", len(wsaErrnos)) + } + for code, name := range wsaErrnos { + got := mapHostErrno(int64(code)) + _, named := errnoNumberOf(name) + switch { + case want[name] && named: + t.Errorf("%s now has a number; drop it from this list", name) + case want[name] && got != int64(code): + t.Errorf("%d (%s, no class) was changed to %d", code, name, got) + case !want[name] && !named: + t.Errorf("%s has no number on Windows; WSA code %d keeps its own", name, code) + case !want[name] && got == int64(code): + t.Errorf("%d (%s) was not mapped", code, name) + } + } +} + +// TestErrnoOfErrorMapsTheWin32Code: the mapping is applied where the number +// is dug out, so every raiser sees MRI's class, not the raw code. +func TestErrnoOfErrorMapsTheWin32Code(t *testing.T) { + err := &os.PathError{Op: "open", Path: `C:\nope\x`, Err: windows.ERROR_PATH_NOT_FOUND} + if got, ok := errnoOfError(err); !ok || got != errnoNumbers["ENOENT"] { + t.Errorf("errnoOfError = %d, %v; want ENOENT (%d)", got, ok, errnoNumbers["ENOENT"]) + } + dir := &os.PathError{Op: "remove", Path: `C:\d`, Err: windows.ERROR_DIR_NOT_EMPTY} + if !errIsErrno(dir, "ENOTEMPTY") { + t.Errorf("ERROR_DIR_NOT_EMPTY is not ENOTEMPTY") + } + if errIsErrno(dir, "ENOENT") { + t.Errorf("ERROR_DIR_NOT_EMPTY is ENOENT") } } diff --git a/internal/vm/errno_winsock_other.go b/internal/vm/errno_winsock_other.go deleted file mode 100644 index 192084a7..00000000 --- a/internal/vm/errno_winsock_other.go +++ /dev/null @@ -1,15 +0,0 @@ -// Copyright (c) the go-embedded-ruby/ruby authors -// -// SPDX-License-Identifier: BSD-3-Clause - -//go:build !windows - -package vm - -import "syscall" - -// posixErrno is the identity everywhere but Windows: a POSIX platform's socket -// calls already fail with POSIX errno numbers, so there is nothing to -// translate. See errno_winsock_windows.go for what the Windows half does and -// why the split exists at all. -func posixErrno(e syscall.Errno) syscall.Errno { return e } diff --git a/internal/vm/errno_winsock_windows.go b/internal/vm/errno_winsock_windows.go deleted file mode 100644 index 4fd72393..00000000 --- a/internal/vm/errno_winsock_windows.go +++ /dev/null @@ -1,69 +0,0 @@ -// Copyright (c) the go-embedded-ruby/ruby authors -// -// SPDX-License-Identifier: BSD-3-Clause - -//go:build windows - -package vm - -import ( - "syscall" - - "golang.org/x/sys/windows" -) - -// posixErrno maps a Winsock error to the POSIX errno Ruby reports for it. -// -// Windows socket calls fail with WSAE* codes in the 10000 range, which -// errnoClasses does not name -- so a refused connection arrived as a bare -// SystemCallError where MRI raises Errno::ECONNREFUSED, and `rescue -// Errno::ECONNREFUSED`, the retry idiom this change is about, matched nothing -// on this platform. The windows CI lane found it; darwin and linux were green, -// which is the shape of a divergence that only one lane can see. -// -// MRI does the same translation in rb_w32_map_errno (win32/win32.c), which is -// why a Ruby program written against POSIX errno classes works unchanged there. -// -// The target is syscall's own constant, not a number: on Windows Go defines the -// POSIX errnos above APPLICATION_ERROR rather than at their Unix values, and -// errnoClasses is built from those same constants -- so mapping to the constant -// lands in the table, and errnoStrerror then reports Go's text for it -// ("connection refused", capitalised). Hardcoding 61 would miss on both counts. -// -// The names come from golang.org/x/sys/windows because syscall defines only -// four of them (WSAEACCES, WSAECONNABORTED, WSAECONNRESET, WSAENOPROTOOPT) -- -// found by cross-building, not by CI. x/sys is already a direct dependency of -// this package (filestat_unix.go, spawn_native.go use x/sys/unix). -// -// The table is the socket path only: each entry is a WSAE* code whose POSIX twin -// Ruby code actually rescues. A code not listed keeps its own number and reaches -// the SystemCallError arm, which is the honest answer for one with no POSIX -// meaning. -// -// ⚠ The CLASS is what this decides, and the windows lane asserts it. The MESSAGE -// is not measured against a Windows MRI anywhere here -- there is no Windows -// host on this machine -- so no test claims its exact bytes on this platform. -func posixErrno(e syscall.Errno) syscall.Errno { - if p, ok := winsockToPosix[e]; ok { - return p - } - return e -} - -var winsockToPosix = map[syscall.Errno]syscall.Errno{ - windows.WSAECONNREFUSED: syscall.ECONNREFUSED, - windows.WSAETIMEDOUT: syscall.ETIMEDOUT, - windows.WSAEHOSTUNREACH: syscall.EHOSTUNREACH, - windows.WSAENETUNREACH: syscall.ENETUNREACH, - windows.WSAENETDOWN: syscall.ENETDOWN, - windows.WSAEADDRINUSE: syscall.EADDRINUSE, - windows.WSAEADDRNOTAVAIL: syscall.EADDRNOTAVAIL, - windows.WSAENOTCONN: syscall.ENOTCONN, - windows.WSAEISCONN: syscall.EISCONN, - windows.WSAEINVAL: syscall.EINVAL, - windows.WSAEMFILE: syscall.EMFILE, - windows.WSAEINTR: syscall.EINTR, - syscall.WSAECONNRESET: syscall.ECONNRESET, - syscall.WSAECONNABORTED: syscall.ECONNABORTED, - syscall.WSAEACCES: syscall.EACCES, -} diff --git a/internal/vm/file.go b/internal/vm/file.go index 1f6241d6..b413e604 100644 --- a/internal/vm/file.go +++ b/internal/vm/file.go @@ -1,14 +1,12 @@ package vm import ( - "errors" "os" "os/user" "path" // always '/'-separated, as Ruby's File is — not path/filepath "path/filepath" // OS-native, only for symlink resolution (File.realpath) "sort" "strings" - "syscall" stdtime "time" "github.com/go-embedded-ruby/ruby/internal/object" @@ -583,7 +581,7 @@ func (vm *VM) registerFile() { if err := os.Truncate(p, intArg(args[1])); err != nil { // A negative (invalid) length is Errno::EINVAL; a missing path is // Errno::ENOENT — matching truncate(2) and MRI's rb_file_s_truncate. - if errors.Is(err, syscall.EINVAL) { + if errIsErrno(err, "EINVAL") { raise("Errno::EINVAL", "Invalid argument @ rb_file_s_truncate - %s", p) } raise("Errno::ENOENT", "No such file or directory @ rb_file_s_truncate - %s", p) diff --git a/internal/vm/io.go b/internal/vm/io.go index 957cb198..f1294163 100644 --- a/internal/vm/io.go +++ b/internal/vm/io.go @@ -8,7 +8,6 @@ import ( "os" "strconv" "strings" - "syscall" "time" "unicode/utf8" @@ -1166,7 +1165,7 @@ func raiseFlockErrno(err error, p string) { switch { case errIsErrno(err, "EBADF"): raise("Errno::EBADF", "Bad file descriptor @ rb_file_flock - %s", p) - case errors.Is(err, syscall.EINVAL): + case errIsErrno(err, "EINVAL"): raise("Errno::EINVAL", "Invalid argument @ rb_file_flock - %s", p) } raise("Errno::ENOTSUP", "Operation not supported @ rb_file_flock - %s", p) diff --git a/internal/vm/io_dirty.go b/internal/vm/io_dirty.go index d8f79a28..8317f210 100644 --- a/internal/vm/io_dirty.go +++ b/internal/vm/io_dirty.go @@ -107,10 +107,9 @@ func (o *IOObj) writeDirty(content []byte) error { // raiseFlushErr raises a failed flush as MRI's rb_io_flush_raw does, through // rb_sys_fail_on_write: the errno the system answered, not one guessed from // the path. ENOSPC from a full disk, EISDIR, EROFS all keep their class. On -// Windows the Win32 code is first mapped as rb_w32_map_errno does. +// Windows errnoOfError has mapped the Win32 code as rb_w32_map_errno does. func raiseFlushErr(err error, path string) { if eno, ok := errnoOfError(err); ok { - eno = mapHostErrno(eno) if name, ok := errnoClasses[eno]; ok { raise("Errno::"+name, "%s @ rb_io_flush_raw - %s", errnoStrerror(eno), path) } diff --git a/internal/vm/socket_dialerr.go b/internal/vm/socket_dialerr.go index 50a7c097..353602e6 100644 --- a/internal/vm/socket_dialerr.go +++ b/internal/vm/socket_dialerr.go @@ -7,7 +7,6 @@ package vm import ( "errors" "net" - "syscall" ) // raiseDialErr reports a failed connect the way MRI's socket layer does, which @@ -46,12 +45,9 @@ func raiseDialErr(err error, addr string) { } if eno, ok := errnoOfError(err); ok { // Windows fails socket calls with WSAE* codes in the 10000 range, which - // errnoClasses does not name -- so a refused connection arrived as a bare - // SystemCallError there while darwin and linux were green, and `rescue - // Errno::ECONNREFUSED` matched nothing on the one platform nobody tested - // it on. MRI translates the same way (rb_w32_map_errno); posixErrno is - // the identity everywhere else. - eno = int64(posixErrno(syscall.Errno(eno))) + // errnoClasses does not name; errnoOfError has already mapped them as + // rb_w32_map_errno does, so `rescue Errno::ECONNREFUSED` matches there. + // // An empty addr means the caller has no single peer to name -- the // Net::HTTP transport, where the phase may be a read rather than a // connect and Go's own text already carries the address. Naming